TECHNICAL SHEET
SUB Serie
SUB S 12
Industrial Rotary Switch
SUB Serie
SUB S12 Model
TECHNICAL DRAWING AND CHARACTERISTICS

General characteristics :

Electrical characteristics :

  • Angle between two positions: 30°-60°-90°-120°
  • Max. panel thickness: 5
  • Sealing joints on request
  • Max. operating temperature – dry heat: +125°C
  • Min. operating temperature – dry cold: -55°C
  • Insulation: steatit
  • Switches with solid silver contacts
  • Diameter of cable hole:
    • in contact blades: 1.1 mm
    • in pole-pieces: 1.3 mm
  • Max. voltage: 150V
  • Max. current:
    • with cut: 0.5 A
    • without cut: 3 A
  • Max breaking power: 45 W
  • Contact resistance: 0.01 miliohm
  • Dielectric strength:
    • between non shorting contacts: 3000 Vdc
    • between contacts and pole-pieces: 2000 Vdc
    • between contacts, pole-pieces and ground: 1500 Vdc
  • Insulation resistance:
    • between two adjacent contacts: 1.10^6 Megaohm
    • between contacts and ground: 1.10^5 Megaohm
Dimensions, cotes L
Standard assembly
Shortened assembly
Simple wafer
Double wafer
Simple wafer
Double wafer
1 wafer
26
38
25
35
2 wafers
47
66
44
60
3 wafers
67
95
62
85
4 wafers
88
123
81
109
5 wafers
109
152
99
133
6 wafers
129
180
118
158
For each added wafer
20.5
28.5
18.5
24.5

Nota:
Pour les galettes doubles à 8 et 12 circuits (4 et 6 circuits par face), ajouter 6.5 mm par galette à la cote L

Principales combinaisons réalisables par face de stator en fonction de l'écart angulaire
Ecart angulaire entre 2 positions
30°
60°
90°
120°
Nombre de circuits
1
2
3
4
6
1
2
3
4
1
2
3
1
2
Nombre de positions
12
6
4
3
2
6
3
2
2
4
2
2
3
2
Important:
  • The stops are user adjustable from 2 to 6 or 7 to 12 positions
  • Availlable with 12, 6, 4 and 3 positions on a full turn
    • Version CC: Shorting contacts, (make before break)
    • Version E: Panel sealing, add 2mm to L
    • Version M: Navy quality with or without sealing
    • Version R: Straigth terminals to reduce L
  • Other versions:
    • Gold plated contacts 3µ over nickel plating
    • Open circuit on 6 positions at 60°
    • Biased indexing (momentary contacts)
    • Security system with pull or push to turn
    • Activation by RONIS or KABA key
    • Assembly with counter-turning indexing
    • Hollow shaft (diameter 6 x 3,1 o diameter 10 x 6,1) for mounting with other components (switch, potentiometer)
    • Standard shafts and special shafts

© IEC Electronique - Juillet 2001 -