TECHNICAL SHEET
SUB Serie
SUB A 10
Industrial Rotary Switch
SUB Model
SUB A 10 Model
TECHNICAL DRAWING AND CHARACTERISTICS

General characteristics :

Electrical characteristics :

  • Angle between two positions: 36°-72°
  • Max. panel thickness: 5
  • Sealing joints on request
  • Max. operating temperature :dry heat: +85°C
  • Min. operating temperature :dry cold: -55°C
  • Insulation: Alkyd
  • Switches with solid silver contacts
  • Diameter of cable hole:
    • in contact blades: 1.1 mm
    • in pole-pieces: 1.3 mm
  • Max. voltage: 150V
  • Max. current:
    • with cut: 0.5 A
    • without cut: 3 A
  • Max breaking power: 45 W
  • Contact resistance: 0.01 miliohm
  • Dielectric strength:
    • between non shorting contacts: 3000 Vdc
    • between contacts and pole-pieces: 2000 Vdc
    • between contacts, pole-pieces and ground: 1500 Vdc
  • Insulation resistance:
    • between two adjacent contacts: 1.10^6 Megaohm
    • between contacts and ground: 2.10^5 Megaohm
Dimensions, cotes L
Standard assembly
Shortened assembly
Simple wafer
Double wafer
Simple wafer
Double wafer
1 wafer
26
38
26
37
2 wafers
48
66
46
62
3 wafers
69
95
65
85
4 wafers
89
123
83
111
5 wafers
110
152
102
135
6 wafers
130
180
120
160
For each added wafer
20.5
28.5
18.5
24.5

Note:
For double wafers with 8 poles (4 poles per stator face), add 6,5 mm per wafer to L

Principal combinations available per stator face according to angular gap
Angle between 2 positions
36°
72°
Number of poles
1
2
4
1
2
Number of positions
10
5
2
5
3
Important:
  • The stops are user adjustable from 2 to 5 or 6 to 10 positions
  • Availlable with 10 and 5 positions on a full turn
    • Version CC: Shorting contacts, (make before break)
    • Version E: Panel sealing, add 2mm to L
    • Version M: Navy quality with or without sealing
    • Version SP: Solder terminals are replaced by solder pins for PCB mounting
    • Version R: Straigth terminals to reduce L
  • Other versions:
    • Gold plated contacts 3µ over nickel plating
    • Biased indexing (momentary contacts)
    • Security system with pull or push to turn
    • Activation by RONIS or KABA key
    • Assembly with counter-turning indexing
    • Hollow shaft (diameter 6 x 3,1 o diameter 10 x 6,1) for mounting with other components (switch, potentiometer)
    • Standard shafts and special shafts

© IEC Electronique - Juillet 2001 -