| TECHNICAL
SHEET |
CH
Serie
|
CH
16 Programmable
|
|
|
Industrial
Rotary Switch
CH Serie
CH 16 PROGRAMMABLE Model
|
|
| TECHNICAL
DRAWING AND CHARACTERISTICS |
|
|
|
General
characteristics:
|
Electrical
characteristics:
|
- Shaft diameter: 6
mm
- Tie rod diameter:
1,5 x 0.30
- Temperature range :
-55°C +85°C
- Insulation :
Noryl
- Silver plate bronze
contacts
|
- Max. voltage: 150
V
- Max. current :
- with cut :
0.2 A
- swithout cut :
0.5 A
- Switch rating :
15 W
- Contact resistance :
<15 milliohm
- Dielectric strentgh :
- between two adjacent
terminals: 1500 Vdc
- between terminals
and commons : 1000 Vdc
- between terminals,
commons and ground : 2000 Vdc
- Insulation resistance :
- between two adjacent
terminals : >2.10^6 Mégaohms
- betweent terminals
and ground : >5.10^5 Mégaohms
|
|
Dimensions,
cotes L
|
|
|
Total
cell dimensions, L
|
|
1 cell
CH16
|
39.8
|
|
Concentric
mounting: 1 cell CH 16 + 1 cell CH 16
|
83
|
|
| Important: |
|
The serie CH Programmable consist
of 3 types: CH 32, CH 16 and CH 8 equipped with 32, 16 and 8 working
contacts respectively
- Further to the standard
bridge combinations, they can be programmed to order by using
the grid on the following pages
- Exist with 3 positions at
120°, 6 at 60°, 8 at 45°, 10 at 36°, 12 at 30°,
14 at 25°45', 16 at 22°30',20 at 18°, 24 at 15°,
28 at 12°51', 32 at 11°15' and 40 positions at 9°
without stop
- The stop pins are user adjustable
- It is possible to assemble
2 cells CH32 or 1 cell CH32 + 1 cell CH16 or still 1 celle CH32
+ 1 cell CH8 on the same shaft
Important notice:
Each group of 2 contacts is
independent and can be considered as a switch; the CH 32 for example
contains 32 switches. This system requires however that the inner
terminals are connected to create the common circuit. The outputs
are available at the opposite terminals:
- Version F: Threaded bushing
for panel mount, or smooth bushing S
- Version E: Panel sealing
(without increase in L), if no sealing N
- Version XC: shorting contacts,
if not, only X
- Other versions: Hollow shaft
(diameter 6 x 3,1) for concentric mounting with other components
(switch, potentiometer). In that case a mounting bracket can be
supplied (specify diameter of mounting hole)
- Activated by RONIS or other
etc... key (please consult us)
- Gold plated contacts
|
© IEC Electronique
- Juillet 2001 -
|